U shape auto duct line 5Mini auto duct line 5Auto duct line 5Auto duct line 3Auto duct line 2Duct Line 5 U shapeDuct Line 5Duct line 3Duct line 2Auto coil LineSpiral tubeformer PD1602 +plasma cutSpiral tubeformer PD1602Spiral tubeformer PD-1500Mold type spiral tubeformerFlexible spiral duct making machineFlat oval duct making machinehydraulic elbow makerElectric elbow maker machineDuct elbow makerSpot welderRound flange forming machineRotary beading machine3 roller rolling machineAngle iron bending machineCNC plasma cutting machineDuplex TDF flange former T-16-2 with cleatDuplex TDF flange former T-16-2 without cleatTDF flange forming machine T12TDF flange forming machine T15TDF flange forming machine T16TDF flange forming machinePittsburgh lock forming machine SA-12HBPittsburgh lock forming machine SA-15HBS&C cleat lock forming machine SA-12SRound duct lock forming machine SA-12CLock forming machineManual folding machine 1300mm to 2500mmManual TDF folding machine 1300-2500mmPneumatic TDF folding machine 1300Electric duct folding machineAmerican standard folding machineCNC hydraulic Press BrakeDuct folding/bending machineHand held seam lockerPneumatic seam lockerHydraulic seam lockerPittsburgh seam lockerTDC flange machine with grooveTDC flange forming machine without grooveTDC flange machinePower Fastener for TDC fasteningDuct beader 1300mmDuct beader 2000mmDuct beading machinePower slitting machineAutomatic TDF corner making lineManual TDF corner lineTDF corner moldTDC corner moldG clamp moldTDF/C G Clamp Corner punching machinePneumatic TDF corner maticsPortable hydraulic TDF corner maticsTDF corner maticsElectric shearing machineHydraulic guillotineShearing machineElectric angle iron bening machineHydraulic angle iron bending machineAngle iron flange forming machineCNC plasma cutting machineCleat benderTDF flange formerPittsburgh lock formerTDF folding machinePortable seam lockerDuct beaderRotary beader crimperBeader and SlitterDuct MachineAuto Duct production linesU Shape Auto Duct Line 5Linear Shape Auto Duct Line 5Auto Duct Production Line 3Auto Duct Production Line 2Mold type spiral tube former machineCNC Plasma Cutting MachineCNC Angle Iron Production LineAuto hydraulic gorelocker machineElectric gore locker machineHydraulic OvalizerSheet metal edge hemming machineFatory videosMessagesNews

Duct Machine Power Setup for Export Markets - Voltage Guide

  1

Every commissioning engineer on our team has at least one airport story that starts with a power problem. The line arrived, the crane set it in place, and then the electrician opens the panel and asks why the main breaker is rated for 50 Hz when the shop feed is 60. Or the phases are there, but the voltage sags to 340 V under load because the shop ran a skinny cable 80 meters across the floor. Power setup is the single most preventable source of bad commissioning weeks, and it costs nothing to get right if you plan before the container ships.

This is the checklist conversation I have with buyers in the Middle East, Southeast Asia, and South America before we build their machine. Use it before you place an order, because retro-fitting transformers and control gear after arrival is slow and expensive.

The nameplate, decoded

Chinese duct machinery ships with 380 V / 50 Hz / 3-phase as the default, with a 4-wire plus ground scheme. That suits a big slice of the world: the Gulf states run 400 to 415 V at 50 Hz, which a standard machine tolerates within its plus-or-minus 10 percent window. Vietnam runs 380/400 V at 50 Hz. Fine. The trouble zones are the true 60 Hz markets and the low-voltage three-phase markets.

What actually happens if you ignore the mismatch? Induction motors overspeed at 60 Hz if voltage stays at 380 nominal, roughly 20 percent faster, with torque dropping off. Servo drives and VFDs mostly cope, because they rectify to DC internally, but cheap drives and contactor coils suffer. Hydraulic power packs run hot. I have watched a plasma station's cooling pump cook itself in a Philippines shop running 230 V 60 Hz into a 380 V 50 Hz motor. It ran. For eleven minutes.

Market by market: what you will actually find on the wall

MarketIndustrial supplyFrequencyWhat to order / check
UAE, Saudi Arabia, Qatar400 - 415 V, 3-phase50 HzStandard config; check phase sequence and earth
Vietnam380 - 400 V, 3-phase50 HzStandard config; expect unstable voltage in industrial zones, add stabilizer
Philippines220 - 230 V, 3-phase60 HzOrder 230 V / 60 Hz motors or a step-up transformer; verify all drives
Thailand380 - 400 V, 3-phase50 HzStandard config
Indonesia400 V, 3-phase (plants)50 HzStandard config; gensets common, check capacity
Brazil220 V or 380 V, 3-phase60 HzOrder 60 Hz motors; confirm which 3-phase voltage the city actually delivers
Chile, Peru, Colombia220 - 380 V, 3-phase60 HzOrder 60 Hz configuration; confirm voltage city by city
Mexico220 V or 440 V, 3-phase60 HzOrder to match; 440 V is common in factories

The takeaway: 50 Hz Gulf markets are nearly plug-and-play. The 60 Hz belt from Mexico down through Brazil is where orders need to be written differently on the purchase contract.

Motors, drives, and what to change for 60 Hz

For a full auto duct line, the motors split into two families. Main drives on the feed, the bead station, and the folding station are usually VFD-fed, and those are the easy ones: the drive re-scales its output, so a 50 Hz motor on a VFD can run a 60 Hz map with correct voltage-to-frequency ratio. Ask the supplier to reprogram drive parameters for 60 Hz input and confirm the motor's insulation class and cooling are acceptable at the higher speed. In practice this works, and it is the standard path we take.

Direct-on-line motors are the ones that bite. Hydraulic pump motors, coolant pumps, and some older-design shear drives run straight off the supply. Those must be re-wound or swapped for 60 Hz equivalents, or fed through a transformer that fixes voltage but not frequency. A transformer alone does not fix frequency. I have had to explain that on site more than once, sadly after installation day.

Control circuits are a separate loop. Most of our machines run 220 V or 110 V control power derived from a control transformer inside the cabinet. Confirm the control transformer primary matches your supply, and check whether the PLC power supply module accepts the range. Almost all modern ones take 100 to 240 V AC wide-range, but confirm it in writing.

Servos, plasma, and the picky loads

Servo amplifiers on modern duct lines are wide-range input, typically 3-phase 323 to 506 V on a 380 V-class unit. On a 220 V 3-phase 60 Hz site, the clean solution is a 220-to-380 V step-up transformer feeding a dedicated servo cabinet, or specifying 220 V class drives at order time. The plasma unit is its own conversation: plasma power sources are frequently single-phase or 3-phase 220/230 V class regardless of machine voltage, and they draw hard, 15 to 25 kW spikes at arc start. Give the plasma source its own feed and do not hang it on the same breaker as the line's servo cabinet, or every arc start becomes a brown-out event for the whole machine.

Generator-powered shops, common in parts of Indonesia, the Philippines, and West Africa, need a hard look at capacity. A mid-size auto duct line with plasma draws peaks near 30 kVA. Add start-up surges from the hydraulic pack, and I recommend a genset rated at least 2.5 times the running load, with an AVR. A line fed by an overloaded genset shows up as random servo alarms and plasma arc restarts that nobody can reproduce when the supplier's engineer is on a video call.

Grounding and phase sequence: the unglamorous killers

Two site-side issues cause more damage than voltage itself. First, grounding. A duct shop floor with no proper earth rod, or with the machine chassis bonded to a water pipe, will eventually feed noise into the PLC and kill inputs. We ask for an earth resistance below 4 ohms at the machine. It is a ten-minute measurement and it protects a machine that costs more than the building's roof.

Second, phase sequence. Motors on direct-on-line circuits, plus the cooling fans, will run backwards if two phases are swapped. Modern panels include a phase-failure and sequence relay, but many buyers delete it to save cost. Do not. The relay costs less than one reversed hydraulic pump.

Cable sizing and the last 80 meters

Here is a scenario that repeats somewhere in the world every month. The buyer installs a proper main breaker, then runs the machine feed in leftover 4 mm cable because "the distance is short." Voltage drop in a cable is a function of length, current, and cross-section, and a duct line at 60 amps on thin cable over 50 meters can easily lose 5 percent or more before the current even reaches the machine. Combine that with a soft utility feed and your servos start tripping on undervoltage at the worst moments, mid-fold, mid-cut.

Size the feeder cable for the machine's listed full-load current plus 25 percent headroom, and keep the voltage drop under 3 percent from panel to machine. For a typical mid-size line that means 16 mm copper for runs up to about 50 meters, and 25 mm beyond that, but let your local electrician confirm against your code. Put the machine on its own breaker. Sharing a feed with welding stations, compressors, or a paint booth guarantees voltage dips exactly when the plasma strikes an arc.

Heat, dust, and the control cabinet

Gulf buyers should pay attention to ambient rating. A control cabinet specified for a 40 degree C workshop will struggle in a warehouse that touches 50 in summer, especially with a plasma unit dumping heat nearby. Ask for cabinet cooling, a fan-filter or a small air conditioner on the electrical cabinet, and keep the cabinet out of direct sun through the roller doors. Dust from the plasma table is the second enemy; positive-pressure cabinet ventilation with filtered intake keeps boards clean. These are small line items at order time and impossible retrofits afterward.

What to write into the purchase contract

Put the electrical spec in the order itself, not in a WeChat message. Three lines: supply voltage and frequency of the installation site; a request that all motors and drives be configured for that supply; and a statement that the control cabinet includes phase sequence protection and a wide-range PLC power supply. Attach a photo of the shop's main breaker and the utility bill if you want to be thorough. A good manufacturer will send back a one-page confirmation. If they will not, buy elsewhere.

Then prepare the site side before the container lands: cable cross-section from the main panel to the machine location, sized for the machine's listed current plus 25 percent headroom; a dedicated breaker; and the earth rod. For reference on what a configured machine family looks like, our TDF flange former pages list the electrical ratings per model, and the same logic applies across the range.

If any of this is murky, just tell us your site voltage and frequency before ordering. A one-line answer from you saves a week of commissioning later.

Frequently asked questions

Can I just use a step-up transformer for a 220 V 60 Hz shop?

It fixes voltage but not frequency. VFD-fed drives will usually work; direct-on-line motors must be 60 Hz rated. So a transformer is part of the answer, never the whole answer.

Does 415 V instead of 380 V damage the machine?

No. 415 V sits inside the standard tolerance window for 380 V equipment. Check voltage at the machine under load, not just at the panel.

What genset size do I need for an auto duct line with plasma?

Plan for roughly 2.5 times the running load. For a typical line with plasma cutting, that means a 75 kVA genset minimum, with AVR, dedicated to the machine.

Is the control voltage the same worldwide?

Control circuits are internal to the cabinet, usually 110 V or 220 V derived from a transformer. Confirm the primary side matches your supply; the machine's behavior does not change.